Temperature Controllers www.tempco.com | (800) 323-6859 | email: [email protected] 13-47 Power Input Standard: 90 - 250 VAC, 47-63 Hz, 10 VA, 5W maximum Optional: 11 - 26 VAC / VDC, 10 VA, 5W maximum Signal Input Resolution: 18 bits Sampling Rate: 5 samples / second Accuracy: ±.24% of span typical Maximum Rating: -2 VDC minimum, 12 VDC maximum (1 minute for mA input) Temperature Effect: ±1.5 μV / °C for all inputs except mA input ±3.0 μV / °C for mA input Sensor Lead Resistance Effect: T/C: 0.2μV/ohm 3-wire RTD: 2.6°C/ohm of resistance difference of two leads Burn-out Current: 200nA Common Mode Rejection Ratio (CMRR): 120 dB Normal Mode Rejection Ratio (NMRR): 55 dB Sensor Break Detection: Sensor open for TC, RTD and mV inputs; sensor short for RTD input; below 1 mA for 4-20 mA input; below 0.25V for 1-5V input; unavailable for other inputs Sensor Break Response Time: Within 4 seconds for TC, RTD and mV inputs; 0.1 second for 4-20 mA and 1-5 V inputs Output 1 / Output 2 Relay Rating: 240 VAC, 2 Amp Pulsed Voltage: Source voltage 5V, Current limiting resistance 66Ω Linear Output — Characteristics Type Tolerance Zero Tolerance Span Capacity Load 4-20 mA 3.6-4.0 mA 20-21 mA 500Ω max 0-20 mA 0 mA 20-21 mA 500Ω max 0-5 VDC 0 VDC 5-5.25 VDC 10 KΩ min 1-5 VDC 0.9-1.0 VDC 5-5.25 VDC 10 KΩ min 0-10 VDC 0 VDC 10-10.5 VDC 10 KΩ min Resolution: 15 bit analog to digital converter Output Regulation: 0.02% for full load change Output Settling Time: 0.1 sec. (stable to 99.9%) Isolation Breakdown Voltage: 1000 VAC Temperature Effect: ±0.01% of span/°C Solid State Relay (Triac) Output Rating: 1A / 240 VAC Inrush Current: 20A for 1 cycle Min. Load Current: 50 mA rms Max. Off-state Leakage: 3 mA rms Max. On-state Voltage: 1.5 VAC rms Insulation Resistance: 1000 Megohms minimum at 500 VDC Dielectric Strength: 2500 VAC for 1 minute Alarm 1 — Programmable Alarm 1 Relay: Form A, (NO) Maximum rating: 240 VAC, 2 Amp Alarm Functions: Dwell timer Deviation High / Low Alarm Deviation Band High / Low Alarm Process High / Low Alarm Sensor Break Alarm Alarm Mode: Normal, Latching, Hold, Latching / Hold Dwell Timer: 0 - 4553.6 minutes Data Communications Interface: RS-232 (1 unit), RS-485 (up to 247 units) Protocol: Modbus Protocol – RTU mode Address: 1-247 Baud Rate: 0.3 - 38.4 Kbits/sec Data Bits: 7 or 8 bits Parity Bit: None, Even or Odd Stop Bit: 1 or 2 bits Communication Buffer: 160 bytes User lnterface Dual 4-digit LED Display: 0.55" (14 mm) Red Process 0.40" (10 mm) Green Setpoint Keypad: 4 keys Programming Port: For automatic setup, calibration and testing Control Mode Output 1: Reverse (heating) or direct (cooling) action Output 2: PID cooling control, cooling P band 50-300% of PB On-Off: 0.1 - 90.0°F hysteresis control (P band = 0) P or PD: 0 - 100.0% offset adjustment PID: Fuzzy logic modified Proportional band: 0.1 - 900°F Integral time: 0 - 1000 seconds Derivative time: 0 - 360 seconds Cycle Time: 0.1 - 90 seconds Manual Control: Heat (MV1) and Cool (MV2) Auto-tuning: Cold start and warm start Failure Mode: Auto-transfer to manual mode with sensor break or A-D converter damage Ramping Control: 0 - 900°F/min or 0 - 900°F/hr ramp rate Environmental and Physical Operating Temperature: 14 to 122°F (-10 to 50°C) Storage Temperature: -40 to 140°F (-40 to 60°C) Humidity: 0 to 90% RH, non-condensing Dielectric Strength: 2000 VAC, 50/60 Hz for 1 minute Dimensions: 3-3/4 × 3-3/4 × 2-9/16" (96 × 96 × 65 mm) H×W×D Depth behind panel: 2" (53 mm) Panel Cutout: 3-5/8" × 3-5/8" (92 × 92 mm) H×W Weight: 0.55 lb. (250 grams) Approval Standards Safety Standard: UL61010C-1 EN61010-1 (IEC1010-1) Protective Class: IP 50 front panel standard, all indoor use. NEMA 4X/IP65 front panel if specified. IP 20 housing and terminals with protective cover. EMC: EN61326 Part Number Input Out 1 Out 2 Alarm TEC56001 tc relay none relay TEC56002 tc relay none none TEC56003 tc 4-20 mA none none TEC56004 tc dc pulse none none TEC56005 RTD relay none none TEC56006 RTD DC pulse none none TEC56007 RTD DC pulse relay none TEC56008 RTD DC pulse none relay Rear Terminal Connections Stock and Common Part Numbers (Power Input: 90-250 VAC, no data com, no NEMA 4X)