Temperature Controllers www.tempco.com | (800) 323-6859 | email: [email protected] 13-20 Model TEC-2500 1/32 DIN Temperature Controller Output 1 BOX 3 1 = Relay: 2A / 240 VAC 2 = Pulse DC for SSR drive: 5 VDC (30 mA max) 3 = Isolated, 4-20 mA (default), 0-20 mA 4 = Isolated, VDC, 1-5 (default), 0-5, 0-1 5 = Isolated, VDC, 0-10 6 = Triac-SSR output 1A / 240 VAC C = Pulse DC for SSR drive: 14 VDC (40 mA max) 9 = Other Output 2 / Alarm 2 BOX 4 0 = None 1 = Relay: 2A / 240 VAC 2 = Pulse DC for SSR drive: 5 VDC (30 mA max) 3 = Isolated, 4-20 mA (default), 0-20 mA 4 = Isolated VDC, 1-5 (default), 0-5, 0-1 5 = Isolated VDC, 0-10 6 = Triac-SSR output 1A / 240 VAC 7 = Isolated 20V @ 25 mA DC, Output Power Supply 8 = Isolated 12V @ 40 mA DC, Output Power Supply 9 = Isolated 5V @ 80 mA DC, Output Power Supply C = Pulse DC for SSR drive: 14 VDC (40 mA max) A = Other Power Input BOX 1 4 = 90-264 VAC 5 = 11-26 VAC / VDC 9 = Other Communications BOX 6 0 = None 1 = RS-485 Interface 2 = RS-232 Interface 3 = Retransmission 4-20 mA (default), 0-20 mA 4 = Retransmission 1-5 VDC (default), 0-5 VDC 5 = Retransmission 0-10 VDC 9 = Other Alarm 1 BOX 5 1 = 5 VDC Logic Output 9 = Other Units — °F or °C BOX 7 1 = °F on faceplate 2 = °C on faceplate 3 = None (process units) Configurable for 4 Programmable Outputs! Signal Input — Universal, can be programmed in the field BOX 2 1 = Input 1 – Universal input (factory default = tc type J) Thermocouple: J, K, T, E, B, R, S, N, L RTD: PT100 DIN, PT100 JIS Current: 4-20 mA, 0-20 mA Voltage: VDC, 0-1, 0-5, 1-5, 0-10 Input 2 – not available if RS-232 is specified CT: 0 - 50A AC current Transformer (factory default) Voltage Input: 0-1V, 0-5V, 1-5V, 0-10V Event Input 9 = Other Agency Approvals: RoHS Design Features ✴ 1/32 DIN size – 24 mm × 48 mm ✴ Fuzzy Logic PID Autotune heat & cool control ✴ Short panel depth – only 3-7/8" (98 mm) required ✴ Universal input, field configurable (Type J T/C default, PT100, mA, V) with high accuracy 18-bit D-A ✴ Heater Break Alarm using 0-50 Amp current transformer ✴ Output 2 can be programmed as output or alarm ✴ NEMA 4X / IP65 gasketed front panel ✴ Alarm 1 – programmable 5 VDC logic output ✴ Universal input power, 90-264 VAC or 11-26 VAC/VDC ✴ Bumpless transfer to manual mode during sensor failure ✴ Power limiter output ✴ Wide variety of alarm mode selections ✴ RS-485 and RS-232 data communications interface ✴ Bright 0.40" (10 mm) LED display ✴ Fast input sample rate (5 samples/second) ✴ Automatic programming ✴ Differential control ✴ “Soft-Start” ramp and dwell timer ✴ Analog input for remote setpoint and current transformer ✴ Event input for changing functions and setpoint ✴ Hardware lockout plus remote lockout protection ✴ Loop break alarm ✴ Analog retransmission ✴ DC power supply outputs ✴ High performance at a low price Transformer for Heater Break Alarm (0-50 Amp current) Part Number: TEC99999 Specifications on page 13-47 1 2 3 4 5 6 7 A Part Number based on the hardware code and any software pre-programming will be issued at time of order. Hardware Code: TEC-2500- Note: Detailed information on features common to digital microprocessor-based TEC temperature controls and the complete Table of Input Range and Accuracy can be found on page 13-46. File #: E244198