Temperature Controllers www.tempco.com | (800) 323-6859 | email: [email protected] 13-44 Model TEC-7100 3/16 DIN Temperature Controller Design Features ✴ 3/16 DIN size – 72 mm × 72 mm ✴ Fuzzy Logic PID Autotune heat and cool control ✴ Short panel depth – only 2-9/16" (65 mm) required ✴ Universal input, field configurable (Type J T/C default, PT100, mA, V) with high accuracy 18-bit D-A ✴ Highly versatile – 6 types of inputs available ✴ Output 2 can be used for cooling function ✴ Universal input power – 90-250 VAC or 11-26 VAC/VDC ✴ Optional NEMA 4X/IP65 front panel ✴ Bumpless transfer to manual mode during sensor failure ✴ Wide variety of alarm mode selections ✴ Optional RS-485 communications interface ✴ Bright 0.40" (10 mm) red LED process display 0.31" (8 mm) green LED setpoint display ✴ High performance at a low price Output 1 BOX 3 1 = Relay: 2A / 240 VAC 2 = Pulse DC for SSR drive: 5 VDC (30 mA max) 3 = Isolated, 4-20 mA (default), 0-20 mA 4 = Isolated, VDC, 1-5 (default), 0-5, 0-1 5 = Isolated, VDC, 0-10 6 = Triac-SSR output 1A / 240 VAC C = Pulse DC for SSR drive: 14 VDC (40 mA max) 9 = Other Output 2 BOX 4 0 = None 1 = Relay: 2A / 240 VAC 2 = Pulse DC for SSR drive: 5 VDC (30 mA max) 3 = Isolated, 4-20 mA (default), 0-20 mA 4 = Isolated VDC, 1-5 (default), 0-5, 0-1 5 = Isolated VDC, 0-10 6 = Triac-SSR output 1A / 240 VAC 7 = Isolated 20V @ 25 mA DC, Output Power Supply 8 = Isolated 12V @ 40 mA DC, Output Power Supply 9 = Isolated 5V @ 80 mA DC, Output Power Supply C = Pulse DC for SSR drive: 14 VDC (40 mA max) A = Other Alarm BOX 5 0 = None 1 = Relay: 2A / 240 VAC, SPDT 9 = Other Communication BOX 6 0 = None 1 = RS-485 Interface 3 = Retransmission 4-20 mA (default), 0-20 mA 4 = Retransmission 1-5 VDC (default), 0-5 VDC 5 = Retransmission 0-10 VDC 9 = Other Signal Input— Universal, can be programmed BOX 2 in the field for item 5 or 6 5 = Thermocouple: *J, K, T, E, B, R, S, N, L 0-60mV 6 = RTD: *PT100 DIN, PT100 JIS 7 = 0-1 VDC 8 = *0-5, 1-5 VDC A = 0-10 VDC B = *4-20, 0-20 mA 9 = Other * indicates default value NEMA 4X / IP65 BOX 7 0 = No 1 = Yes Configurable for 4 Programmable Outputs and optional NEMA 4X/IP65 Front Panel! Note: Detailed information on features common to digital microprocessor-based TEC temperature controls and the complete Table of Input Range and Accuracy can be found on page 13-46. 1 2 6 7 3 4 5 A Part Number based on the hardware code and any software pre-programming will be issued at time of order. Hardware Code: TEC-7100- Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC 9 = Other Agency Approvals: File #: E244198